Steca Solarix PRS
The simplicity and high performance of the new Steca Solarix PRS solar charge controller
make it particularly attractive. At the same time, it offers a modern design and
a convenient display, all at an extremely attractive price. Several LEDs in various
colours emulate a tank dispkay, which
gives information on the charge status of
the battery.Here, Steca's latest algorithms are employed in order to guarantee optimal
battery maintenance. The Solarix PRS charge controllers are equipped with an electronic
fuse, thus ensuring the optimal protection. They operate on the serial principle,
and seperate the solar module from the battery in order to protect it against overcharging.
The Solarix PRS charge controllers are universal charge controllers, which means
they can be used with lead-acid batteries or get batteries without the need for
complex configuration settings. For large projects, the charge controllers can also
be equipped with special functions. these include the night light function, and
selectable charging plateau and deep-discharge protection voltagges.
Functions
- Low-loss serial controller
- PWM-controlled constant-voltage charging
- Battery charging with automatic charging mode selection (floast, boost, equal)
- Recongnises and caries out a maintenance charge (boost charge every 30 days if idle)
- Automatically adjust to the voltage level 12 V/24 V
- Current-dependent load deactivation
- Automatic load reactivation
- Temperature compensation
- Grounding on the plus side
- Integrated self test (start voltage 17.0 V)
- Made in Germany (development and production)
Display
- separate LEDs to display the battery charge status
- LEDs (red/green) to display the function status
Electronic protection functions
- Battery-overload protection (HVD)
- Deep-discharge protection (LVD)
- Automatic electronic fuse
- Reverse-polarity protection at module input, of the load and the battery connetion
- Reverse-polarity protection of the module
- Short-circuit protection of the load and the module
- Good electronmagnetic compatibility
- dling protection in case no battery is connected
- Prevention of back current into the module
- Integrated temperature copmpensation of the end-of-charge voltage (0
�C to +50 , factor
-4mV/K/cell)
Download Technical Specifications (pdf)